StorCase S11J100 Ficha de datos Pagina 52

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 68
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 51
42 RAID Configuration
StorCase Technology, Inc. InfoStation 5-Bay RAID User's Guide - Rev. C00
2. Select one of the following policy options:
Manual Rebuild - Requires the user to manually initiate a rebuild of
the volume
Automatic Rebuild - Forces the Daemon to initiate the rebuild process
automatically and minimize the possibility of data
loss
3. If Automatic Rebuild is selected, the user will have the following additional choi-
ces:
Immediate Rebuild - Causes the Daemon to rebuild immediately follow-
ing detection of an offline drive
Rebuild Only If Needed - Delays the rebuild of a SAFE volume with an offline
drive until the write occurs to the SAFE volume
4. Click Accept to implement selected options.
The Daemon will use the specified rebuild policy to maintain redundancy. The Sta-
tus window will display a rebuild in process.
Figure 13: Policy Specification
Vista de pagina 51
1 2 ... 47 48 49 50 51 52 53 54 55 56 57 ... 67 68

Comentarios a estos manuales

Sin comentarios